SUNPRO POWER
SP440-N108M10
N-type TOPCon · Black Frame
This is the module we use in AIDEX solar packages for homes.
- power
- 440 W
- module efficiency
- 22.53 %
- 1722 × 1134 mm · compact format
- 21 kg
Why this panel
N-type TOPCon technology
Modern N-type monocrystalline TOPCon cells — 108 half-cells per module.
Up to 22.53% module efficiency
The 440 W version reaches 22.53% efficiency — more power from every square metre of roof.
Compact residential format
1722 × 1134 mm and 21 kg — a size that fits residential roofs well.
Black frame
A black frame for a clean, even look on the roof.
IP68 connectors
MC4-compatible connectors rated IP68 against dust and water.
Made for rooftop systems
The module is designed for residential rooftop solar systems.
Technical specification
General
- Manufacturer
- SUNPRO POWER
- Model
- SP440-N108M10
- Series
- SPxxx-N108M10 Black Frame (410–440 W)
- Technology
- N-type TOPCon
- Number of cells
- 108 half-cells
- Cells
- N-type monocrystalline, 182 × 91 mm
Electrical
- Rated power (STC)
- 440 W
- Power classes in series
- 410–440 W
- Module efficiency
- 22.53 %
- Max. system voltage
- DC 1500 V (TÜV)
- Max. series fuse
- 25 A
Construction
- Glass
- 3.2 mm ultra-clear embossed tempered coated glass
- Frame colour
- Black
- Dimensions
- 1,722 × 1,134 × 30 mm
- Area
- 1.95 m²
- Weight
- 21 kg
- Connector
- MC4-compatible, IP68
Electrical data (440 W)
| Electrical data (440 W) | STC | NMOT |
|---|---|---|
| Pmax (W) | 440 | 329 |
| Vmp (V) | 32.09 | 29.90 |
| Imp (A) | 13.72 | 11.00 |
| Voc (V) | 38.53 | 36.10 |
| Isc (A) | 14.43 | 11.63 |
Specification according to the manufacturer’s official product information. Technical data may change; the current manufacturer documentation prevails. Manufacturer product page · Manufacturer website
Packages with this panel
Let’s start with your home’s estimate
Share your address and consumption — we’ll prepare the recommended system and an individual quote.
- An individual solution for your home
- SUNPRO POWER N-type TOPCon panels
- Your request creates no obligation
Package configurations and estimates are for information only. We prepare the final system design and an individual quote after assessing your property.